Eliminates 99.999% of Bacteria Within 1 Minute Over a 24-Hour Period

Report No.: VX-TR-21-0630

Method: EN 13727:2012+A2:2015 (E)

Eliminates 99.999% of Bacteria Within 1 Minute Over a 24-Hour Period

PURPLE continues to kill 99.999% of Bacteria within 1 minute even after a 24-hour holding duration.

Abstract

These are the results of a quantitative suspension test for the evaluation of bactericidal activity in the medical area according to EN 13727:2012+A2:2015 (E)

PURPLE (24 hours holding duration) showed the required microbial reduction of ≥5.0 log10 against test strains Enterococcus hirae ATCC 10541, Escherichia coli K12 NCTC 10538, Pseudomonas aeruginosa ATCC 15442, Proteus vulgaris NCTC 4635, and Staphylococcus aureus ATCC 6538 in accordance with EN 13727:2012+A2:2015 (E) at 100.00 %* concentration after 1 minute under the stated conditions. 

According to the simple acceptance decision rule, there is a minimal risk of false acceptance.

Dr Peter Cheong Chiew Hing
Head of Microbiological Testing
Viroxy Labs, Kuala Lumpur

The test result relates only to the sample stated in the full test report. The above analysis is based solely on the sample submitted. Information on measurement uncertainty is available upon request. For further enquiries, please contact us.